Water Saving ControllerAn uncontrolled 3 gallon urinal system flushing just
4 times an hour, 24 hours a day, 365 days a year uses over 100,000 gallons of water per annum. The cost is between £500 and £1000 each year per urinal. How does Sensaflow work?The Heart of the system is the passive infra red unit which detects occupancy and opens the solenoid valve to flush the urinal. It provides an optional hygiene flush which comes into operation if no occupancy occurs. It is adjustable between one and 48 hours and a one to 256 minutes occupancy variation.
At the point of installation the unit is programmed to memorise the 'fill time' and will continue to fill the cistern accordingly. The hand-held master programmer plugs into the unit via a standard communications socket, allowing the unit to be interrogated. Valuable information can be extracted on a simple keypad. This includes the number of flushes and the ability to open and close the valve in order to check the performance of the system. The sensor unit operates up to a distance of six metres. Settings are recorded via the unit's non volatile memory. In the event of power failure or battery change the 'stored' settings are retained. |
Greenflow, 27 Brunel Way, Mart Road Industrial Estate, Minehead, Somerset TA24 6AH
Mobile: 07742 752069 Email: Greenflowwatersaving@gmail.com